BATTERY CHARGERS: 75 -
240 WATTS (9840, 9740, 2045 series)
- 3-step charge control with timer
- 75W, 150W and 240W models
- Compact switch mode design
- Charge current not affected by input voltage fluctuations
- Protected against reverse polarity
- LED indicators with three different colours
- Available with medical approval, EN60601
- Safety approval AS3260: CS7485N
- EMC approved, CE marked
- Medical approval EN60601, 9740 & 9840 models
TECHNICAL SPECIFICATIONS |
| |
| Input voltage |
240 VAC (198 – 264), 50 ~ 60Hz |
| Charge voltage |
14.7V for 12V systems
29.5 V for 24V systems
Other voltages on request
|
| Float voltage |
13.8V for 12V systems
27.6V for 24V systems
|
| Power |
9840 model: 75 watts
9740 model: 150
watts
2045 model: 240 watts
|
| Load regulation |
Typically <200mV |
| Line regulation |
Typically <20mV |
| Switching frequency |
63kHz |
| Leakage current |
<2.5mA for 12V battery |
| Operating temperature |
-10°C to +40°C |
| Ripple |
<100mV pk-pk 12V models |
| Efficiency |
83% at rated load and input |
| Current limiting |
Yes |
| Insulation class |
Class I |
| Safety standards |
EN60335-1, EN60601-1, EN60950, AS3260 |
| EMC |
Emission: EN50081-1
Immunity: EN50082-1
|
| Indicators |
ORANGE = Constant current
YELLOW = Constant
voltage timer on
GREEN = Constant voltage float mode
|
| Timer |
Typically 2 hours ±30min |
| Construction |
IP21 enclosure |
| Tterminals |
- Input mains cable and plug
- Battery clips
|
| Weight |
Model 9840: 1.45kg
Model 9740: 1.7kg
Model 2045: 1.7kg
|
| Dimensions |
Model 9840: 158 x 171 x 54mm
Model
9740: 184 x 171 x 54mm
Model 2045: 148 x 210 x 68mm
|
| Model |
Volts out Cycle |
Volts out Float |
Amps |
Rec. Batt. Ah |
| 9740-12 |
14.7 |
13.7 |
10 |
40-400 |
| 9740-24 |
29.5 |
27.4 |
5 |
20-200 |
| 9740-36 |
44.1 |
40.8 |
3.3 |
15-150 |
| 9740-48 |
58.8 |
54.8 |
2.5 |
10-100 |
| 9840-12 |
14.7 |
13.8 |
5 |
20-120 |
| 9840-24 |
29.5 |
27.4 |
2.5 |
10-60 |
| 2045-12 |
14.7 |
13.8 |
20 |
100-1000 |
| 2045-24 |
29.5 |
27.4 |
10 |
50-500 |
|
| |
|
BATTERY CHARGERS: 50 WATTS
(2040 series)
- 3-step charge control with timer
- Universal input 100 ~ 240 VAC
- Charge current not affected by input voltage fluctuations
- Protected against reverse polarity
- LED indicators with three different colours
- Medical approval, EN60601
- Safety approval AS60950 – N19260
- IEC 320 3-pin input connector
- EMC approved, CE marked
OPTIONS
- Mounting bracket “2040-bracket”
TECHNICAL SPECIFICATIONS |
| |
| Input voltage |
100 – 200 VAC ± 10%, 50
~ 60Hz |
| Charge voltage |
14.7V for 12V systems
29.5 V for 24V systems
|
| Float voltage |
13.8V for 12V systems
27.6V for 24V systems
|
| Power |
Maximum 50 watts |
| Load regulation |
Typically <200mV |
| Line regulation |
Typically <100mV |
| Switching frequency |
45kHz |
| Leakage current |
<100µ A @ 12V
<200 µ A @ 24v
|
| Operating temperature |
-10°C to +40°C |
| Ripple |
<100mV pk-pk |
| Efficiency |
81% at rated load and input |
| Current limiting |
Yes |
| Insulation class |
Class I |
| Safety standards |
EN60335, AS60950, EN60950, EN60601 |
| EMC |
Emission: EN50081-1
Immunity: EN50082-1
|
| Indicators |
RED = Constant current
YELLOW = Constant
voltage timer on
GREEN = Constant voltage float
mode
|
| Timer |
Typically 2 hours ±30min |
| Construction |
Desk top style |
| Output terminals |
Two core cable and battery clips |
| Weight |
350 g |
| Dimensions |
135 x 80 x 44mm |
| Model |
Volts out Cycle |
Volts out Float |
Amps |
Rec. Batt. Ah |
| 2040-12 |
14.7 |
13.8 |
4.0 |
15-90 |
| 2040-24 |
29.5 |
27.6 |
2.0 |
7-45 |
|
| |
 |
BATTERY CHARGERS: 40 WATTS
(9940 series)
- 3-step charge control with timer
- Universal input 100 ~ 240 VAC
- Charge current not affected by input voltage fluctuations
- Protected against reverse polarity
- LED indicators with three different colours
- Medical approval, EN60601
- Safety approval AS60950-N19260
- Optional battery clips or barrel type output connector
- IEC 320 2-pin input connector
- EMC approved, CE marked
OPTIONS
- Mounting bracket: “9940-Bracket”
- Also available as a simple Float Charger
TECHNICAL SPECIFICATIONS |
| |
Input
voltage |
100 ~ 240 VAC ± 10%,
50 ~ 60Hz |
Charge
voltage |
14.7V for 12V systems
29.5 V for 24V systems
Other voltages on request |
Float
voltage |
13.8V for 12V systems
27.6V for 24V systems |
Power |
Maximum 40 watts |
Load
regulation |
Typically <200mV |
Line
regulation |
Typically <100mV |
Switching
frequency |
45kHz |
Leakage
current |
<100µ A
@ 12V
<200µ A @ 24V |
Operating
temperature |
-10°C to +40°C |
Ripple |
<100mV
pk-pk |
Efficiency |
81% at rated load and
input |
Current
limiting |
Yes |
Insulation
class |
Class II |
Safety
standards |
EN60335-1, EN60335-2-29,
AS60950, EN60950, EN60601 |
EMC |
Emission: EN50081-1
Immunity: EN50082-1 |
Indicators |
RED = Constant current
YELLOW = Constant voltage timer on
GREEN = Constant voltage float mode |
Timer |
Typically 2 hours ±30min |
Construction |
Desk top with optional
mounting bracket |
Output
terminals |
Battery clips optional
or barrel plug type
12 x 5.5 x 2.1mm (L, DO, DI) |
Weight |
250 g |
Dimensions |
107 x 67 x 37mm |
| Model |
Volts out Cycle |
Volts out Float |
Amps |
Rec. Batt. Ah |
| 9940-12 |
14.7 |
13.8 |
2.3 |
9-60 |
| 9940-24 |
29.5 |
27.6 |
1.3 |
4-30 |
|
| |
 |
BATTERY CHARGERS: 40
WATT (9640 series)
- 3-step charge control with timer
- Plug-in unit, switch mode design
- Charge current not affected by input voltage fluctuations
- Protected against reverse polarity
- LED indicators with three different colours
- Medical approval, EN60601
- Safety approval AS3260: N155923
- Optional battery clips or barrel type output connector
- EMC approved, CE marked
|
| |
| Input voltage |
240 VAC (190 – 264), 50 ~ 60Hz |
| Charge voltage |
7.35V for 6V systems
14.7V for 12V systems
29.5 V for 24V systems
Other voltages on request |
| Float voltage |
6.9V for 6V systems
13.8V for 12V systems
27.6V for 24V systems |
| Power |
40 watts maximum |
| Load regulation |
Typically <200mV |
| Line regulation |
Typically <200mV |
| Switching frequency |
45kHz |
| Leakage current |
<100µA |
| Operating temperature |
-10°C to +40°C |
| Ripple |
<20mV pk-pk 12V models |
| Efficiency |
81% at rated load and input |
| Current limiting |
Yes |
| Insulation class |
Class II |
| Safety standards |
EN60335-1, EN60335-2-29, AS3260, EN60950,
EN60065 |
| EMC |
Emission: EN50081-1
Immunity: EN50082-1 |
| Indicators |
RED = Constant current
YELLOW = Constant voltage timer on
GREEN = Constant voltage float mode |
| Timer |
Typically 2 hours ±30min |
| Construction |
Plug pack with mains input plug |
| Output terminals |
Battery clips optional or barrel plug
type
12 x 5.5 x 2.1mm (L, DO, DI) |
| Weight |
250 g |
| Dimensions |
100 x 51 x 63mm without plug |
| Model |
Volts out Cycle |
Volts out Float |
Amps |
Rec. Batt. Ah |
| 9640-6 |
7.35 |
6.9 |
2.7 |
11-60 |
| 9640-12 |
14.7 |
13.8 |
2.7 |
11-60 |
| 9640-24 |
29.5 |
27.6 |
1.5 |
5-30 |
|